Manual 26166V2 MicroNet Simplex & MicroNet Plus Woodward 1 Contents This manual is divided into two volumes: Volume 1 contains chapters 1–9 (manual 26166V1). The self-documenting GAP software allows control engineers to custom design a control system for any application. Servlink OPC Server (SOS) The SOS Servlink OPC Server is an OPC server designed to communicate with a control using the. 27. The Woodward MicroNet™ Controller is a state-of-the-art programmable, digital controller. ) Siemens Simatic S7 My experience cover Installation, Commissioning, Maintenance,, and troubleshooting in Gas Turbine Technology, Process. Daily planning for the team of Technical instrumentation. Certified as an IEC61508 SIL-3 (Safety Integrity Level 3) safety device. GAP 4 software is Woodward’s pictures-to-code programming tool. 08 or higher. Call or email the Woodward Turbine Help Desk: 1-970-498-3095 [email protected] Service and Support. The Coder software tool is designed to support the creation and compiling of GAP applications for use in Woodward product lines. 2 The MicroNet Safety Module’s versatile inputs, outputs, programming environment, and communications make it ideal as a safety protection device for use in applications that could possibly reach an unsafe state or condition and that must communicate directly to the plant DCS. The 4th generation of GAP was released in 2018. The inputs on this module will range from zero to five volts or four to twenty milliamperes. Shell Petroleum -Shell Petroleum Port Dickson, Malaysia Retrofit Elliot PLC to Woodward Vertex Pro (simplex) control systems. Explore our wide range of solution and product offerings. Backwards compatible to all MicroNet Plus modules supported under Coder 6. Woodward Product and Application Training. MicroNet TMR’s superior architecture and diagnostic coverage combine to create a system with 99. Woodward is the world’s largest independent designer and manufacturer of energy control solutions, including governors, actuators, and controls for industrial engines, turbines, and power equipment. One of the key features of this sensor is that there are no potentiometers and thus will not require adjustments or calibration when the module is being inserted into the chosen chassis. The Vertex-Pro is built on Woodward’s field-proven MicroNet™ platform, and is available in simplex or dual-redundant models. The setup should be similar. The GEN II control software evolvedAn electric utility grid connected test facility has been established at Silicon Valley Power (SVP) in Santa Clara, California to validate the reliability, availability, maintainability and durability (RAMD) of a commercial-ready catalytic combustor system (XONON). Woodward’s Graphical Application Programmer (GAP™) 4 Editor utilizes a fourth-generation language developed by Woodward. Monitor GAP 4 is a licensed software service tool that allows service personnel to view and tune runtime values for GAP (Graphical Application Program) generated application software. We're here for you, call, email, or open a helpdesk ticket. (Rev. The 5009FT control must be in a shutdown mode and the speed of the turbine must be 0 RPM. Repairable. CPUs occupy either one (simplex) or two (redundant). The MicroNet platform can now be integrated as a safety PLC to create an IEC 61508 SIL-3 safety certified system. Reftrofit of a 20 MW GE Steam Turbine Generator using state-of-art Woodward MicroNet redundant processing control as speed governor, extended remote IO, three HMI interfaces, one data server and. 11 Introduction; 11 Quick Start Guide;Woodward MicroNet TMR 5009FT Installation And Hardware Manual. From Netcons to today’s Micronet controls, We have access to core software to support and service your equipment. Application Note 51459 MicroNet Plus CPU5200 Cyber Security Woodward 3 Cyber Security Upgrade Paths Upgrade Considerations Cyber-ready units—part numbers 5466-1045 (CPU) & 5466-1046 (RTN)—Product Manual 26728 (Revision A, 6/2018) Original Instructions MicroNet™ Product Family “Kitted” Safety System Manual Installation and Operation ManualThe 5501-409 unit from Woodward Inc is a six-slot motherboard that was designed as part of the MicroNet Digital Control series. Designed for easy integration with Woodward controls like MicroNet Plus. - Moog Integrating Servo Valve - Various Emerson field transmitters Results • Operational impact - 7-8 % increased productivity. MODULE - MICRONET TMR KERNEL P. Woodward Micronet Plus Controller & GAP Tool Trained in Poland Elblag GE. COMPATIBILITY: To use this version of GAP/Coder, you must use GAP Editor 3. Woodward continues to invest heavily in the MicroNet product line to ensure its marketThe Singapore Training Centre offers theoretical and practical training on many Woodward products. Woodward recommends using AppManager. This board is another one of the main triple modular redundant (TMR) power supply boards that operate on two hundred and twenty volts of alternating current. A user account on Woodward. This module is specifically designed as a MicroNet-Plus module that can be used in Simplex or Redundant I/O modules. Page 1 Product Manual 26167V1 (Revision J, 5/2014) Original Instructions ® MicroNet TMR Digital Control This manual replaces manual 85584 for the MicroNet TMR. 2015 D-R Controls engineer on Final commissioning of 2 GTC units. MicroNet™ Digital Control Platform. 5501-367 Woodward FTM Modules. Woodward’s over 150 year history of providing in-depth service and support across industrial applications around the globe have been a trusted solution for all of our customers. Product Description. Woodward’s servos, power cylinders, and current-to-pressure converters are used globally for hydro applications of inlet guide vanes and nozzle valve control. Woodward's MicroNet TMR (Triple Modular Redundant) controller is a customizable digital control platform that reliably controls and protects steam, gas turbines, and compressor trains used in system-critical applications where the chance of a safety issue or large economic loss may be possible. This might cause the newer coder version to fail. Woodward’s hydro turbine control history started in 1870 and has grown to be the trusted solution in managing small, medium and large hydro plant applications around the world. The MicroNet Controller is a state-of-the-art, programmable, digital controller. The Woodward 5501-467 Simplex Power Board operates on an input voltage of two hundred and twenty volts of alternating current or direct current. 5466-1146. With four times more processing power, the MicroNet-Plus CPU modules incorporate additional functionality. Woodward 03333 p. the MicroNet controls are set up in a redundant configuration, with a secondary MicroNet chassis serving as a hot backup control the case of failure of the primary unit. The MicroNet Plus, 505, Flex500 and Atlas-II controls are designed so that all interface, maintenance, and troubleshooting is done via. The outputs are the same as the inputs but are also 600 Ohms. Our factory service provides high quality technicians and original factory parts to evaluate, clean, replace, assemble. Product Description. Contact Woodward to determine which. This seat license is used to authorize a NetSim Basic software program, and only includes a program authorization serial number for one computer (seat). Being completely 9927-2131_E. Table of Contents. This module can be removed and inserted live from the MicroNet Plus chassis. Woodward is an independent designer, manufacturer, and service provider of control solutions for the aerospace and industrial markets. 2 MicroNet Plus Control Chassis The MicroNet Plus control is available in two chassis sizes to accommodate different space requirements. Look up your Woodward product by serial number. exe. Woodward has integrated patches provided by Wind River into the CPU. Woodward model 5466-1035 was designed for the MicroNet series. Product Description Controls upgrade from Mark VI and Fanuc 90-70 to Woodward MicroNet Plus, the latest evolution of the MicroNet control system that has been developed for Aero LM product lines. Urgent/11 Patch – MicroNet P1020 CPU Issue As announced in August of 2019 (see Security Bulletin 01661), a set of vulnerabilities known as. The 5466-258 module is a Simplex Discrete Input/Output unit. The MicroNet TMR®(triple modular redundant) controller is a state-of-the-art digital control platform designed to reliably control and protect steam turbines, gas. Woodward MicroNet TMR Installation And Operation Manual ECM3 Electronic Fuel Injection Control F-Series Actuator and Integrated Throttle Body E3 Lean Burn Trim System MicroNet TMR 5009 Digital Control System Woodward ProTech TPS Product Manual the TS160 product manual. Find Woodward, GE, and Unknown for sale on Machinio. Call for Availability: 5466-1035 Woodward model 5466-1035 is a MicroNet Plus CPU5200 unit. Woodward’s MicroNet™ Plus customizable control system is a flexible, state-of-the-art system specifically designed for controlling gas and steam turbines. 9927-2151_A. MicroNet 5466-5001 MicroNet Speed Sensor, 4 Channel, Eddy Probe CH1/ MPU 5464-414 5464-834 MicroNet 5466-5002 MicroNet Speed Sensor, 4 Channel, MPU CH 1-2, Prox CH 3-4 5464-844 MicroNet 5466-5003 MicroNet Speed Sensor, 4 Channel, MPU CH1-3, Prox CH 4 5464-850 Use the above modules with Coder Version 4. The 5466-409 module is a unit that can only be used in a simplex operation, if used in a redundant operation errors will occur. 5. The MicroNet Plus control system provides a flexible platform to control any prime mover and its associated processes including: High-speed control functions. CPU capability, application software recursion rates and determinism, software algorithms, I/O signal conditioning and filtering, and numerous other features combine with long-term support and Woodward service to ensure a. This unit will be used with MicroNet-Plus models that feature simplex or redundant CPUs. 1)9927-1237_AN. Manual 26167 consists of 2 volumes (26167V1 & 26167V2). exe. 2014. SWISS ABB, FUJI JAPAN, BENTLY NEVDA VIBRATION SYSTEM, SIMENS PCS7, GE PROCIFY IFIX Trained. The 5466-1002 module can be used with redundant or simplex CPUs. Being completely9927-2131_E. Call or email the Woodward Turbine Help Desk: 1-970-498-3095 [email protected] is the latest Graphical Application Programmer tool for use with versions 3. It is easy for anyone familiar with the basic structure of ladder logic to write and use Woodward Ladder [email protected] manual describes the Woodward VxWorks RTOS (Real Time Operating System) software tools available to remotely configure and interact with the MicroNet Plus, 505, Flex500 and Atlas-II control platforms. For customers specifically wanting additional spares of the old versions, Woodward is offering a Last Time Buy (LTB) opportunity. Both chassis reserve four slots for redundant power supplies, with the remaining slots available for VME modules (CPUs and I/O modules). MICRONET SAFETY MODULE FAULT TOLERANT PROTECTION SYSTEM W/ VOTED INPUTS (VOL. This model contains a multitude of features such as 128 MB DDR RAM and a real-time clock. The MicroNet Plus devices are VME-based expandable control. The MicroNet Plus control system provides a flexible platform to control any prime mover and its associated processes. (product spec 03346) Woodward 51237 p. Integrated with Woodward’s Control Assistant program which provides tabular display and optionally live value trending; Can be used with Woodward’s NetSim™ Control Simulator or with a live control ; GAP 3. Download PDFExperienced Technician with a demonstrated history of working in the utilities industry. The 5466-1046 module was produced by Woodward Inc as part of their MicroNet Digital Controller series, which was designed as a MicroNet Plus Cyber CPU5200 unit. Application Note 51459 MicroNet Plus CPU5200 Cyber Security Woodward 3 Cyber Security Upgrade Paths Upgrade Considerations Cyber-ready units—part numbers 5466-1045 (CPU) & 5466-1046 (RTN)— Call or email the Woodward Turbine Help Desk: 1-970-498-3095 TurbineHelpDesk@woodward. 390456905-WOODWARD-ACTUOTOR-CATALOGE-pdf-1. One primary feature of this unit is that it can be used in redundant or simplex modes. The Woodward WDE driver is a Woodward implementation of Modbus Over UDP, Standard modbus over ethernet uses TCP. DS200PTBAG1A is a Protective Core Terminal Board Manufactured By General Electric under Mark V Controls Systems. Woodward unit 5466-1146 is a MicroNet Plus RTN unit that is Cyber Security Licensed and features CSAm AEX, and CE (EMC) compliance types. Product Description. See below for the actual license texts. The Hyper facility used a commercial Woodward Micronet© control system for data acquisition, control logic development, operation, and safety assurance. 00-4. Woodward Product and Application Training. exe. The MicroNet TMR. • 2-out-of-3 voting increases system fault coverage close to 100%, which provides an availability of 99. Figure 4-4Mounting Template of MicroNet Plus 14-Slot I/O Chassis. MicroNet TMR with Custom Application using 5466-1247 or -1347 CPU’s and RATIO_LIM2 GAP Block: If using 5466-1247 CPUs, use AppManager 3. 2—Installation The modules slide into card guides in the control's chassis and plug into the motherboard. The Woodward 5501-467 Simplex Power Board operates on an input voltage of two hundred and twenty volts of alternating current or direct current. During 20th to 24th February 2017, PM Control Systems (Singapore) welcomes our friends from General Electric Oil and Gas for a week long training program in our Singapore training facility. Courses are offered at the Factory as well as the Woodward distributors and service partners worldwide. - AX Control Technician. $1,519. Product Description. 2 MicroNet Plus Control Chassis The MicroNet Plus control is available in two chassis sizes to accommodate different space requirements. Tel: +1 647 243 85554 Email: info. 3. Woodward MicroNet TMR 5009FT Installation And Hardware Manual Woodward 505XT Product Manual Woodward MicroNet TMR Installation And Operation Manual ECM3 Electronic Fuel Injection Control F-Series Actuator and Integrated Throttle. As a MicroNet Plus Cyber CPU5200 model, this board can be used to load Control software, which is also known as GAP software. Woodward MicroNet Digital Controller Power Supply Module 5466-1001 has a power input of 110 VAC/125 VDC and is also a MicroNet-Plus unit. de 2013 5 meses. The 5466-1035. 18e, Ladder Logic 2. 00 or later (this is a new numbering system, Coder MicroNet 1. Courses are offered at the Factory as well as the Woodward distributors and service partners worldwide. More activity by Brennan This vertical turbine harnesses the wind generated by passing vehicles to create energy. (excl. Le signal d’entrée/sortie de (4 à 20) mA. 9927-1846_A. We have the stock available in. 31 MB. o GE Woodward 301/501Controls o GE Mark IV Controls o Woodward Micronet + Controls o Plant Metso (or similar) DCS o Allen Bradley PLC software o Both GE Aero and GE Frame Gas Turbines o Vibration Controls o Boiler Controls. Product Manual 26167V3 (Revision NEW, 10/2016) Original Instructions MicroNet TMR Digital Control Manual 26167 consists of 3 volumes (26167V1, 26167V2, & 26167V3). GAP 4 added the capability for On-Line changes to MicroNet Plus and included several other enhancements for all GAP products. The unit was produced by Woodward as part of the MicroNet Digital Control series which can also be used with a Vertex-Pro Chassis. Operating System software versions 6. But other New Feature Requests and Bugfixes were addressed as well as reported through the. The MicroNet Plus control system provides a flexible platform to control any prime mover and its associated processes. as gas turbines, compressor control and protection, gas and diesel engines, steam. Usage : THE PHOENIX CONTROLS is aware that you need 5453-279 – WOODWARD MICRONET TMR 12-SLOT CHASSIS – Refurbished urgently. MICRONET PLUS 14 SLOT CHASSIS - REDUNDANT. Woodward 03375 p. Use the Save As option in the File pull-down menu of the Servlink toolbar to save the new file under the “C:Program FilesWoodwardServlink Server” directory. 00. e. This module can be used in both Simplex and Redundant systems. WOODWARD 8280-488 REV D 723 PLUS DIGITAL CONTROL 9906-619 REV E. 6881 Woodward Dr, Brentwood Bay, BC is a single family home that contains 2,488 sq ft and was built in 1990. The MicroNet* Plus control system provides high-speed closed loop control, system. g. The Service Pack will upgrade any MP1020 CPU Footprint to 5418-7799 Revision C. 00-5. Woodward's powerful software service tools provide service personnel with extensive monitoring and troubleshooting for the MicroNet Plus. One primary feature of this unit is that it can be used in redundant or simplex modes. The board uses three chassis slots. 10, 3. Product Manual 26166V3 (Revision A, 6/2019) Original Instructions MicroNet™ Simplex Digital Control MicroNet™ Plus Digital Control Manual 26166 consists of 3 volumes (26166V1, 26166V2 & 26166V3) MicroNet TMR Chassis —18 slot chassis. Woodward MicroNet 5200 CPU Module 5503-325 is inserted into the MicroNet Plus/Simplex chassis, for a 2-rack configuration, there is only one of these modules. According to the 06960 Data Sheet which lists the active CPU modules and their current status the 5466-1045 unit is currently inactive meaning that the model can no longer be produced by Woodward. São Paulo e Região, Brasil Instalação de Campo, pré-comissionamento, comissionamento and start-up para turbo máquinas. 999% availability and reliability. 06-7, VxWorks, 32bit GAP 4. 5466-1045 PLCs/Machine Control from WOODWARD 2-Year Warranty, Radwell Repairs - DISCONTINUED BY MANUFACTURER, PLC CPU MODULE, MICRONET PLUS,. This is the tool for graphically configuring ProTech/MicroNet SM controls and for compiling GAP for ProTech/MicroNet SM projects for NetSim simulation. This controller utilizes Woodward’s field-proven MicroNet TMR® triple-redundant, fault-tolerant hardware platform combined with Woodward’s state-of-the-art XT steam control core and algorithms. Recommended Update for Aero Customers using Woodward MicroNet Plus 5200 CPU. Description The MicroNet Plus control is a VME-based, modular control system with redundant or simplex CPU and power supply options and a variety of I/O module. 08, 4. Woodward’s standard off the-shelf control systems are designed to control Francis, Kaplan and Pelton hydro turbines. From Woodward MicroNet & NetCons to 501 controls, MSHS has access to parts and core software to service your equipment. Woodward’s Graphical Application Programmer (GAP) functional block diagram programming language is used for custom programming of Woodward control systems. The logic and parameter ramps were performed on Woodward's Graphical Application Programmer (GAP4©), and sent to hardware actuators (e. 3. Woodward is an independent designer, manufacturer, and service provider of control solutions for the aerospace and industrial markets. 999% availability and reliability. • Configuration of Woodward MicroNet TMR 5009FT & Woodward Speed Protection ProTech GII. 3 inches high x 12. 1)Woodward MicroNet TMR Control System. The Pentium/NT CPU provides a Modbus over TCP/IP Ethernet alternative that allows the use of commercially available Distributed I/O products. Will Your Controls Meet Your Future Needs? Our. One key feature of this board is that when in the MicroNet. system providing six separately regulated, 24 V, 6 A outputs (three from each<br />. Learn More. com PO Box 1519, Fort Collins CO 80522-1519, USA 1000 East Drake Road, Fort Collins CO 80525, USA Phone +1 (970) 482-5811 Email and Website—Woodward has company-owned plants, subsidiaries,. The 5466-1145 unit was designed by Woodward as a MicroNet Plus CPU5200 unit to be used in a redundant or simplex control system. XX platform. MicroNet Plus n accordance with IEC 61508, TÜV Rheinland has approved the MicroNet Plus to. 2. Application Note 51459 MicroNet Plus CPU5200 Cyber Security Woodward 3 Cyber Security Upgrade Paths Upgrade Considerations Cyber-ready units—part numbers 5466-1045 (CPU) & 5466-1046 (RTN)—According to the 26166v2w manual, the 5466-1036 module is a MicroNet Remote Real-Time Network (RTN) Transceiver (XCVR). This module can be used in both Simplex and Redundant systems. The Pentium/NT CPU provides a Modbus over TCP/IP Ethernet alternative that allows the use of commercially available Distributed I/O products. Vulnerability In FortiOS | CVE-2022-40684. Repair services will be available up to 5 years after module inactivation, depending on component availability. MicroNet Plus with Coder MicroNet 1. Information on the 5466-1001 can be found in the 26166V2 manual. Woodward’s MicroNet™ Plus customizable control system is a flexible, state-of-the-art system specifically designed for controlling gas and steam turbines. To use this version of GAP/Coder, you must use Control. - It is the current GE production standard for the LM2500 and the LM6000 product lines. It contains 5 bedrooms and. 5501-376 Woodward FTM Modules. According to the 26166V1 manual when this unit is being used redundantly two CPUs must be used, they can be CPU5200 or CPU5200L modules. Monitor GAP 4 is a licensed software service tool that allows service personnel to view and tune runtime values for GAP (Graphical Application Program) generated application software. Download - MICRONET SIMPLEX/MICRONET PLUS DIGITAL CONTROL (VOL. This unit is the most preferred TMR module which means that it is the newest module and. Manual 26336 VxWorks RTOS Software Tools for MicroNet/Atlas-II . IS200TRLYH3E is a General Electric Mark VI series Relay Terminal Board used in gas turbine control systems. 3-phase Input Power . Applicatons Woodward’s Graphical Application Programmer (GAP™) utilizes a fourth-generation language developed by Woodward. The self-documenting GAP software allows control engineers to custom design a control system for any application. 5009XT. Warranty. ACTUATION. The MicroNet PlusTM control is a VME-based, modular expandable control system with redundant or simplex CPU and power supply options and a variety of I/O module choices. 08, 4. The 5466-1520 module is labeled as a P1020 CPU as part of the MicroNet Digital Controller series produced by Woodward Inc. OBSOLETE. Add to. Page 1 (1 - 10 from 20) 5453-759. Condition. This Version only supports the MicroNet TMR and MicroNet Plus platforms. WOODWARD MICRONET+ WOODWARD MICRONET+ < Go Back | View Enquire List. 999% availability and reliability. . Woodward 03375 p. Turner-ECS team meticulously carried out. - AX Control Tech Team. Datasheet link Previous: Woodward 5466-318 MICRONET TMR KERNEL P. The MicroNet TMR Power Supply Chassis ensures seamless power distribution to vital modules. com is required to access protected information. Great team work for ADNOC Offshore project 👏Woodward 5466-1045 Rev. The training facility contains several demonstration models and simulation set-up for standard and customized Woodward controls and applications. GAP 4 software is Woodward’s pictures-to-code programming tool. This model cannot be used in conjunction with any of the CPU5200 modules since there is no available RTN expansion. Woodward 03375 p. com Technical Experience:-Experienced in Power plant filed installation ,commissioning ,operation & maintenance. Woodward 03333 p. Installed in the Silicon Valley Test Facility (SVTF) is a 1. II programmable control is designed specifically for prime mover control applications such. GAP 2. This protocol allows OPC clients like. This model requires no calibration and has no potentiometers on the faceplate. C) MicroNet TMR® Control System Applications - Woodward. (Rev. pdf - Free download as PDF File (. ) Safety Systems commissioning and maintenance (ESD/SIS, Fire & Gas) – Det-tronics, Honeywell, Kidde, etc. exe. These platforms have CPUs with an Ethernet port(s) and do not have a 2-line display. This program provides you with a clean and quick way to have your installed and spare Woodward MicroNet and Netcon modules re-tested to verify general compliance with original factory specifications. Training received in Woodward Micronet software to troubleshoot and monitor Gas Turbine operations. 00 is derived from the current coder 6. Download. … | Learn more about John Crifasi's work experience, education, connections & more by visiting their. The MicroNet TMR can be applied as a component of. 4. 01-1 is a new release of the Coder for MicroNet TMR controls. , load bank, hot air bypass valve) and real. We have Woodward MicroNet Plus controllers the card part number that drives the LVDTs is 5501-1432 We have worked through the GE trouble guide and ended up replacing the on and off engine cables as requested by GE we have replace the LVDTs and done countless VG Cals. The other thing to note is that Woodward controls do not support 32-bit address types in. Contact Woodward to determine which. English Deutsch Français Español Português Italiano Român Nederlands Latina Dansk Svenska Norsk Magyar Bahasa Indonesia Türkçe Suomi Latvian Lithuanian česk. Woodward MicroNet TMR 5009 Installation/Hardware Manual (118 pages) Digital Control System. MICRONET SAFETY MODULE FAULT TOLERANT PROTECTION SYSTEM W/ VOTED INPUTS (VOL. To navigate through the Ribbon, use standard browser navigation keys. This module is also equipped with many different. We will, therefore, work towards expediting. Download PDF. Woodward 8200-1504, Peak 200 Original Instructions Manual MicroNet TMR 5009 Digital Control System. The MicroNet supports several distributed I/O options. Woodward GAP applications typically use UDP blocks to talk Modbus through Ethernet ports. November 10, 2022. 120V AC/DC, TMR, Configurable. Woodward’s MicroNet™ Plus customizable control system is a flexible, state-of-the-art system specifically designed for controlling gas and steam turbines. At the current time P1020 supports MicroNet Plus. Speed Sensor Smart-Plus Module 9. Turner ECS signed a contract with Woodward to validate and test MicroNet and Netcon chassis and cards. 7. 00 (1) Click a star to rate this product. AppManager and the 5009XT manual 35135 are available at Search for:. This upgrade is the latest evolution of the MicroNet* control system that has been developed for aero LM product lines. e. It is comprised of Woodward’s field-proven MicroNet TMR hardware platform and standard steam turbine Woodward’s MicroNet‐Plus and MicroNet TMR platforms are now certified for use in IEC61508 SIL‐1, SIL‐2 or SIL‐3 (safety integrity level) applications. 00 or later (this is a new numbering system, Coder MicroNet 1. The 5466-1245 module is a Cyber Read CPU5200 with Enhanced Performance. 8kg Details 10. In 2005, Woodward released the MicroNet Plus platform which includes a high-power CPU module with expanded communication capability. Coupled with the highly reliable Woodward MicroNet™ Plus hardware platform, it provides FT8 gas turbine fleet customers with consistent and rapid control of their multi-shaft, high-speed, light-inertia turbine systems while providing them the flexibility to make software changes independently. Redundant CPU applications require two identical CPUs. XX. 15 or higher. The CPU P1020 can be used in two system types, redundant or simplex. 2Installation Figure 4-4 shows the mounting template and fasteners to bulkhead mount the chassis. Training courses are provided for diesel, gas, dual-fuel engine controls, steam or gas turbine controls, generator power management and synchronizer controls, compressor control, and software products. S. This module has twenty-four selectable inputs and eight outputs. Woodward Control Systems like MicroNet Plus can easily program these nodes to gather I/O sensor data from remote locations. All models utilize the MicroNet’s compact 8-slot chassis and robust field termination modules. #LM2500; #woodward Type: Project; Class: Senior Design Project II - Lecture; Subject: Electrical and Computer Engineering; University: Colorado State University; Term: Spring 2008;The original GE Mark VI control system was replaced by a Woodward MicroNet Control System, capable of operating all versions of the LM6000. Woodward 03468 p. 5466-5006 and 5466-5007 for all new MicroNet Plus systems. This module is a MicroNet Plus model that can be used to access information during the operation of the device through AppManager. GE LM2500+ DLE, Dresser-Rand Compressors, Woodward Micronet. For 150 years, Woodward has focused its resources and expertise on delivering proven systems that perform under incredible demands. 5466-315 Woodward MicroNet Analog I/O. The 5009XT is standard-off-the-shelf single extraction steam turbine control for use on industrial steam turbines in reliability-critical applications. Learn more. Redundancy is managed at the operating system level using Woodward’s. Brand: Woodward. 998% or higher. To jump to the first Ribbon tab use Ctrl+[. Mounting Bulkhead mounted or adaptable to 483 mm (19 inches) rack mount back panel. Description. BN3300 . 00-5. If you have any questions regarding purchasing this model, please contact our sales team at (919) 372-8413 for pricing as well as shipping information. For the Woodward Micronet & Engine Control training course, in Elst, The Netherlands, the cost will be: € 2 500. exe file with an older version. 08, 4. VAT, lodging and travel expenses). Table of Contents. SPONSORED. The Pentium/NT CPU provides a Modbus over TCP/IP Ethernet alternative that allows the use of commercially available Distributed I/O products. Manual 26336 VxWorks RTOS Software Tools for MicroNet/Atlas-II . This operating system is used on the MicroNet Plus P1020 CPUs. I am already a member. Third Party Software Licenses OpenSSL . These purpose-built controllers are customized to meet the control, protection, and decoupling functionality required. It was developed from MicroNetTMR GAP Programmer 1. MicroNet Simplex 48/24 High-Density Discrete Input Output (HDDIO) Smart-Plus module 5466-1158 was produced by Woodward in 2010 and requires Coder 5. Please contact a customer service representative for purchase, or to. 5501-465 Woodward MicroNet Power Supplies. 505 Upgrade Kit-Flush Mount. provide load-shared Pwr “A”, Pwr “B”, and Pwr “C” outputs. 998% or higher. Average Delivery 5-20 Days. For this reason, Woodward is providing customers currently running this CPU with a free upgrade to the 5466-1145 Cyber Secure CPU. Woodward model 5466-1035 was designed for the MicroNet series. Supervision of cable installation and hook up from field to package control panels. Product Manual 26167V3 (Revision NEW, 10/2016) Original Instructions MicroNet TMR Digital Control Manual 26167 consists of 3 volumes (26167V1, 26167V2, & 26167V3). com PO Box 1519, Fort Collins CO 80522-1519, USA 1041 Woodward Way, Fort Collins CO 80524, USA Phone +1 (970) 482-5811 Email and Website—Woodward has company-owned plants, subsidiaries, and branches, as well as authorized distributors and Woodward 5 EC‐US ‐L1 Chapter 2. The GAP Editor, template and help file required by GAP to provide ProTech/MicroNet SM programming functionality is included. The MicroNet supports several distributed I/O options. Woodward Governor Company reserves the right to update any portion of this publication at any time. Woodward is an independent designer, manufacturer, and service provider of control solutions for the aerospace and industrial markets.